4.14 Service mode
DF Data failure
If an error occurs in the Main microcomputer (PCB6) that prevents output of
geometry data to the TV set, the microcomputer will replace the missing data with
default data stored in the EPROM (6IC3) module 999.
POR1 Power on reset failure 1
Reset or update failure of module 999 during start up.
POR2 Power on reset failure 2
Reset or update failure of module 999 during start up.
PDD Power down detected failure
Power down failure detected on module 999.
CI Address configuration impossible
Error during address configuration. No address has been allocated because an
excessive number of units has been connected to the Master Link.
- Disconnect all units from the link and reconnect them again one at a time.
TD ML data pulled down
The link is pulled down (Low). This error can occur in the form of a physical short
circuit in the link. In the link drivers, or in the ML master/source circuit module 51
in the TV.
TU ML data pulled up
The link is pulled up (High). This error can occur in the form of a physical short
circuit in the link. In the link drivers, or in the ML master/source circuit module 51
in the TV.
TI Transmission impossible
It is not possible to send data to pin 8 on the V.TAPE or AV socket, probably because
of noise.
TD Data link tied down
The data link connection to pin 8 on the V.TAPE or AV socket is short circuited to
ground.
ST-01 Calibration error too few positions
Not enough positions are read during Stand calibration. The Stand may be blocked.
ST-02 Calibration error too many positions
Too many positions are read during Stand calibration.
ST-03 Calibration error EEPROM
Failure when the Stand offset should be stored in the EEPROM.
ST-04 Calibration error transducer
An invalid position is read from the transducer.
ST-05 Calibration error position
Several readings from the transducer with the Stand in the same position.