Line-in setting and log les 24
Line-in setting and log les
Via USB memory stick
The line-in settings can be changed on BeoLab Transmitter 1 by the content of a le called WPLSETUP.TXT placed on a USB memory stick.
At the same time log les can be dumped to the USB memory stick.
[File formats supported are: FAT 16, FAT32 and lenames only consisting of 8.3 characters].
The WPLSETUP.TXT le and the format for the settings can be obtained as follows:
- Insert an empty USB memory stick into the USB A connector.
The BeoLab Transmitter 1 will then create a le on the USB memory stick with the le name WPL_DUMP.TXT.
- Move the USB memory stick to a PC and using a simple text editor, the setting values can be changed according to the source product used with
the BeoLab Transmitter 1; see table below.
- Change the lename to WPLSETUP.TXT.
All lines starting with ‘;’ (semicolon) are regarded as comment lines.
- Disconnect the BeoLab Transmitter 1 from the mains for at least 60 s.
- Insert the USB memory stick into the USB A connector. (Must remain in the USB A socket for at least 60 s to ensure all logging dumped after
restart).
- Connect the BeoLab Transmitter 1 to the mains. Restart is indicated by the product status LED being solid red
- The BeoLab Transmitter 1 discovers the WPLSETUP.TXT le, and the settings for line-in are set in the BeoLab Transmitter 1.
A le named WPL_DUMP.TXT will be created on the USB memory stick; or alternatively overwrite the existing le of the same name.
If a line with the text: ERROR QUEUE PLEASE is found in the WPLSETUP.TXT le, the error log will be dumped in a le named WPLERROR.TXT when
the USB memory stick is inserted into the USB A connector.
If a line with the text: STORE DFS LOG is found in the WPLSETUP.TXT le, a log le consisting of 1000 entries (in a circle buffer) separated by
semicolon is dumped to the USB memory stick. Entries are changes in the setup of the BeoLab Transmitter 1.
All the above les are or must be located in the root folder of the USB memory stick.
Default values and ranges
Setting value Default Range
Line-in Impedance HIGH HIGH/LOW
RCA trigger level 140 mV RMS 30 to 1000 (high value results in less sensitivity)
RCA time out 900 s 0 to 2550 in steps of 10
Line-in via PL sockets same as RCA time out -
TOSLINK time out 1 s 1 to 2550 in steps of 1
RCA and TOSLINK gain: -3 dB -40 to 10
ALWAYS ON FALSE TRUE ~ connection to speakers are always on, for faster start up. Power consumption is
somewhat higher compared to standby consumption.
FALSE ~ Some start up time may be expected; standby power consumption
ERROR QUEUE PLEASE ;ERROR QUEUE PLEASE = out commented ERROR QUEUE PLEASE /