Commands
3 types of commands are supported: device, output and HVAC commands.
Device commands require a component number (see the Events section above) and can be any of the following:
Press or close
Release or open
Hold
Multi-tap
Select scene
Set LED state
Set level
Raise, Lower or Stop
Possible scene numbers are 0 (OFF) to 32.
Setting levels require a level percentage in the range 0 to 100, and a corresponding fade time.
Valid formats for fade time are SS, SS.ss, MM:SS or HH:MM:SS.
Output commands control a particular zone or output. Note that in general, an ID must have been explicitly
assigned to that zone/output during Lutron system setup.
Output commands can be:
Set level
Raise, lower or stop
Pulse
Setting levels require a level percentage in the range 0 to 100, and a corresponding fade time.
Pulsing an output requires a pulse duration.
Valid formats for fade time and pulse duration are SS, SS.ss, MM:SS or HH:MM:SS.
HVAC commands can control the following parameters:
Heat and cool setpoints
Operation mode
Fan mode
Eco mode
Schedule (follow schedule or hold)
The setpoints require a temperature. The temperature can be given in Fahrenheit or Celsius (a value less than 40 is
interpreted as Celsius, above 40 as Fahrenheit). MLGW automatically converts Celsius to Fahrenheit internally when
communicating with the Lutron system.
KNX / EIB
MLGW can interact with KNX systems by means of shared variables (group addresses). The KNX bus supported is