Bang & Olufsen BeoTime User Manual Page 25

  • Download
  • Add to my manuals
  • Print
  • Page
    / 51
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 24
previous row).
Schedulers accept 2 commands: start and stop. Starting a scheduler will start to produce events at the set times.
The continuous option indicates whether the sequence of events are repeated automatically. Leave this option
unchecked for the scheduler to stop after the last event in the list. Checking this option will cause the scheduler to
loop indefinitely until stopped explicitly by a stop command.
Be careful to provide some way of stopping a continuous scheduler. For example, events from Beo5 or from a
keypad.
Lauritz Knudsen, IHC/Schneider, LexControl
IHC/LexControl programming model consists of physical input and output devices plus function blocks. Function
blocks implement the programming of the system, and the interface between the programming and the actual
components is done by linking physical input signals to function block inputs, and function block outputs to
actuators (dimmers, shade controllers, etc.).
The configuration tool for the controller (LK Visual) saves all the programming and setup in an XML file with
extension .VIS.
This file must be provided to MLGW in order to define the list of resources. Once this file is loaded into MLGW, all
relevant resources are selectable.
Resources available for generating events on MLGW are physical input signals and function block outputs.
Commands are always a logical pulse (True followed by False) on function block inputs. This way, all programming
(scenarios, etc.) is implemented by means of function blocks that can be executed by MLGW.
The Visual project file is absolutely necessary, since there is no way to inspect all of the events occurring on the
controller. Therefore, monitoring information will only be available for already defined resources.
Lutron HomeWorks Interactive
Connecting to a HomeWorks processor
Connections to a HomeWorks processor can be done directly on Ethernet, RS232, or indirectly with a RS232 to
Ethernet interface. This last option is only relevant for older HomeWorks generations that had no network interface.
For RS232, hardware flow control is recommended. Be sure to use a fully wired RS232 cable in this case.
Defining HomeWorks resources
Resources on HomeWorks are keypads (both physical and phantom keypads). Keypads are identified by processor
number, link number and keypad address. Use the monitor tool to verify keypad addresses and button numbering.
Page view 24
1 2 ... 20 21 22 23 24 25 26 27 28 29 30 ... 50 51

Comments to this Manuals

No comments