2.6 Fault flow chart
Fault symptom:
- No function of the PCB7, NTC
Possible cause:
- PCB7, NTC
- Cable W4
- Module 999, Amplifier
Is the loudspeaker in
protection mode?
Visual confirm cable
connection between
Module 999, Amplifier
and PCB7, NTC
Reconnect/replace
cable
Replace PCB7, NTC
Replace Module 999,
Amplifier
To confirm correct operation of the NTC, measure
approx. 9.35V DC at normal room temperature, as
shown in fig 1
(When the temperature is rising, the DC voltage is
going towards 0)
Note:
When the loudspeaker goes into protection mode,
it is nescessarry to disconnect mains and wait one
minute before connecting it again.
Fault symptom:
- No function of S1 and S2
Possible cause:
- Module 999, Amplifier
Is there no function of
switch S1 and/or S2?
Replace Module 999,
Amplifier
No
Yes
Fig1
Red
Black